What is high leg voltage on a Delta secondary

Author

Matthew Shields

Updated on April 30, 2026

The voltage is 208 Volts between phase B and neutral. This is referred to as the high leg. The high leg can be calculated by multiplying the phase A to neutral voltage times 1.732 (120 x 1.732 = 208).

What is a high leg on a transformer secondary?

What is a high leg delta connection? A high leg delta connection is a configuration in which one of the windings in a delta connected secondary of a transformer is centre-tapped and grounded. It is also known as red leg connection or wild leg connection or orange leg connection.

What 3 phase system has a high leg?

Phase B, the “high” leg, is not used for single phase loads. This type of service, which is also known as a “high-leg”, “wild-leg”, “stinger leg”, or “wild phase” service, is common in older manufacturing facilities with mostly three-phase motor loads and some 120 volt single-phase lighting and plug loads.

How many volts is a high leg?

Voltage between A, B or C is three phase 240; voltage between neutral and A or C is single phase 120. That B-neutral “high -leg” or “stinger leg” is 208 volts, and must be marked distinctly, typically with orange, according to electrical codes.

Does an open delta have a high leg?

In Wye-Delta, The three phases or hot wires plus a center tapped neutral comes from the transformer. … In Open-Delta, two hot wires and one neutral wire comes from the large transformer and one hot wire as a high leg delta comes from the smaller transformer.

Which system has a high leg?

A high-leg delta system (also commonly called red leg and wild leg among others) is a common configuration involving a transformer secondary having one winding center tapped with neutral and grounded.

What is Delta high leg used for?

High leg delta, also known as wild-leg, stinger leg, bastard leg or high leg is a type of electrical service connection for three phase electric power installations. It is used when both single and three phase power is desired to be supplied from a three phase transformer.

Is 208 Wye or Delta?

Wye Line-to-Neutral VoltageWye or Delta Line-to-Line Voltage1202081201240230400240415

What is the high leg voltage of a 120 240v 3 phase delta system?

120/240 3 Phase High Leg Delta – High Leg Is 248 volts.

What is the voltage on each leg of 480?

From contributor T: The 480 VAC will be 277 from each hot leg to neutral. In three phase applications, the 480 typically is stepped down to 208 VAC. Then, each hot leg off the step down transformer will be 120 VAC hot to neutral.

Article first time published on

What is the voltage on each leg of 3 phase?

Each of the 3 lines will be carrying 120 volts. If you look at the chart, you can easily see the power output of any 2 lines. If one is at peak, the other line isn’t at peak. That’s why in a 3 phase circuit it’s incorrect to multiply 120 volts times 2 to get 240 volts.

How much power is on each leg of 3 phase?

Power is generated at the utility in three phases that are 120 degrees out of phase with one another at 60 Hz. This simply means that 60 times per second, each individual leg of power makes one peak and valley (a full circle), and all three of the phases together split the cycle into thirds (trisect).

Where is 208 volts used?

The voltage is used in larger facilities to power single phase lighting and larger heating, ventilating, and air conditioning loads.

Is 208v always 3 phase?

208 volts is Line-to-Line Voltage. This three Phase voltage is frequently used in small businesses. … It is 208 volts /1.732 which is 120 volts. The power is brought is as 208 volts 3 Phase and then the Line-to-Neutral Voltage will be 120 Volts.

Is there such thing as 240V 3 phase?

240V 3 Phase Open Delta (3P4W) In the US, 240V Power is provided to small buildings with large loads as 240V 3 Phase Open Delta. It’s like 120 / 240V but also provides 240V 3 Phase for large loads (Machinery, etc.). It’s often called “Wild Leg” of “High Leg” Delta because one leg (Phase B) is different.

Is 208 a single phase?

In the USA, 208V single phase and three phase voltage is one of the standard voltage levels used for commercial applications.

Does 480 have a neutral?

480V 3 Phase Delta is a 3 Wire power configuration and does not include a neutral wire.

How do you determine Wye or Delta?

A wye system is connected in a “Y” shape, or configured in a star shape. In a delta system configuration, the phase voltage is equal to the line voltage. In a wye system configuration, the phase voltage is equivalent to the line voltage divided by the root of 3.

What is the difference between 3 phase delta and 3 phase Wye?

Delta systems have four wires total: three hot wires and one ground wire. Wye systems utilize a star configuration, with all three hot wires connected at a single neutral point. One neutral wire and one ground wire make for a total of five wires in 3-phase Wye systems.

Does Wye have a high leg?

Other types of three-phase supplies are wye connections, ungrounded delta connections, or corner-grounded delta (“ghost” leg configuration) connections. These connections do not supply split single-phase power, and do not have a high leg.

What is considered high voltage?

High voltage is classified as having the potential to cause injury or harm. The ratings of the International Electrotechnical Commission (IEC) consider high voltage to be more than 1,500 volts for DC (direct current) circuits and 1,000 volts for AC (alternating current) circuits.

Is Wye or Delta high voltage?

On machines rated for two voltages, the wye connection is for the high voltage; the delta connection is for the low voltage. For a single voltage rating, most 6-lead machines are capable of wye-delta starting (and will run in delta).

How many phases is 480?

480V can be classified as single and 3 phase circuits. 480V 3 phase circuits are the most common power systems used in US industrial plants and are considered to be low voltage power systems.

Can I use 208v instead of 240v?

In short, just because a 208v motor may be designed to run on 230v or 240v systems by using two power legs from the utility source, that doesn’t mean that it will provide the same output efficiency. You will see differences in performance if you try to use 208v when 240v is typically required.

How do you get 277 from 480?

So if you’re wondering how we get numbers like 208, 277 you use 1.732 (because they’re three-phase voltages). For example 480 / 1.732 = 277 volts, and 120 x 1.732 = 208 volts.

How do I get 120v from 3 phase?

Locate and identify the ground or neutral terminal of the 208-volt 3-phase system. Connect the input terminals of your circuit between any phase conductor and the neutral terminal of the system. This connection point will deliver 120-volts to your circuit.

What is the line voltage in 3 phase system if the phase voltage is 240v?

Also the voltage between any one phase and neutral for a 3 phase system is 240 volts. 440V in 3 phase system is line to line voltage if you calculate per phase voltage then you will get approximate same value as for 1 phase system.

What is the difference between 120 and 208 volts?

Capacity: The main difference between 120V and 208V is that 208V circuits have more power and density, therefore requiring less PDU’s needed in the rack. For example, here’s the two most common circuits at 80% total power: 15A at 120V circuit has capacity for 1.8kW at 80%, equaling 1.44kW.

What's the difference between 480V and 208V?

208V is the voltage between phases of a 3-phase “Y” circuit that is 120V from neutral to any hot. 480V is the voltage between phases of a 3-phase “Y” circuit that’s 277V from hot to neutral.

Is 208 and 230 the same?

When a motor is rated at 208/230 volts this means the motor will operate at the 208 volt rating, not 10% under the 208 volt rating. The motors that are truly intended for 208 volts are nameplated for 200 volts. … Note that the 230 volt will have a wild leg (230 volts to neutral) on that particular leg.

What does 120V 208V mean?

120/208VAC means that power distribution is 3 phase with neutral connection (Y System). 120V represents voltage of each phase to neutral point and 208V represents voltage between any two phases. For balance systems, line to neutral voltage is line to line voltage divided by 1.73 (Sq. root of 3).